Recent Updates
  • Biocompatibility Evaluation of Breathing Gas Pathways in Medical Devices
    Biocompatibility evaluation of breathing gas pathways in medical devices is a powerful tool for the evaluation of contaminants from the air emitted from the device for Volatile Organic Compounds (VOCs) and particulate matter when the gas pathway is intended to contact a patients’ respiratory tract. Standard for Biocompatibility Evaluation of Breathing Gas Pathways in Medical Device...
    0 Comments 0 Shares 269 Views
  • Acute Systemic Toxicity & Pyrogenicity
    The biocompatibility systemic toxicity tests are in vivo systemic tests used to evaluate the impairment or activation of a system, rather than the impairment of individual cells or organs. Acute systemic toxicity tests and pyrogenicity tests are included in the systemic toxicity tests. Acute Systemic Toxicity Testing Acute toxicity is considered to be the adverse effects that occur...
    0 Comments 0 Shares 381 Views
  • Subacute & Subchronic Toxicity
    The Biocompatibility Subacute and Subchronic Toxicity test is used to evaluate the toxicity effects likely to arise from repeated exposures would have on a patient, including any compound toxicity effects. This test determines the systemic effect of repeated doses of materials or their extracts for no less than 24 hours and no greater than 10% of the total lifespan of the test animal. Subacute...
    0 Comments 0 Shares 506 Views
  • Chemical Characterization
    Chemical Characterization is a powerful methodology for addressing biocompatibility endpoints, providing a risk assessment of biocompatibility using chemical, biocompatibility, and patient exposure data. Chemical Characterization involves the extraction of the device with various solvents, chemical analysis of compounds extracted from the device, and an evaluation of the toxicological risk...
    0 Comments 0 Shares 403 Views
  • Sensitization (ISO 10993-10)
    Sensitization testing is used to assess the potential of chemicals and medical devices to cause a delayed hypersensitivity reaction following a single or repeated exposure to the body. Sensitization is one of the three most common biocompatibility tests required to ensure the safety of medical devices. "Tests for irritation and skin sensitization", part ten of the Biological evaluation of...
    0 Comments 0 Shares 388 Views
  • Genetic Toxicology Testing
    Genetic toxicology testing evaluates the potential of the test material to induce the gene mutation or chromosome damage using a range of bacterial, mammalian cells in vitro and in vivo test systems. STEMart offers multiple test types for genotoxicity biocompatibility testing, following the OECD guidelines modified for medical devices and performing under GLP...
    0 Comments 0 Shares 564 Views
  • Hemocompatibility Testing
    Hemocompatibility testing is designed for medical devices contacting circulating blood. Biomaterials that contact blood could have cellular effects and humoral effects including thrombosis, embolism, activation of the coagulation, etc. For devices contacting with circulating blood, hemocompatibility testing is generally required as a biocompatibility assessment. STEMart offers multiple test...
    0 Comments 0 Shares 539 Views
  • The manufacturer of Bio-Rad TC20 Automated Cell Counter is Bio-Rad Laboratories. Model is TC20. The Bio-Rad TC20 Automated Cell Counter is a benchtop instrument that counts mammalian cells in one easy step, starting an automated count immediately after inserting a slide. Innovative autofocus technology and sophisticated digital image analysis algorithms produce accurate cell counts in less than 30 seconds for most samples. https://www.ste-mart.com/bio-rad-tc20-automated-cell-counter-bio-rad-laboratories-115560.htm
    The manufacturer of Bio-Rad TC20 Automated Cell Counter is Bio-Rad Laboratories. Model is TC20. The Bio-Rad TC20 Automated Cell Counter is a benchtop instrument that counts mammalian cells in one easy step, starting an automated count immediately after inserting a slide. Innovative autofocus technology and sophisticated digital image analysis algorithms produce accurate cell counts in less than 30 seconds for most samples. https://www.ste-mart.com/bio-rad-tc20-automated-cell-counter-bio-rad-laboratories-115560.htm
    WWW.STE-MART.COM
    Bio-Rad TC20 Automated Cell Counter, Bio-Rad Laboratories - STEMart
    Bio-Rad TC20 Automated Cell Counter, Bio-Rad Laboratories. Used of cell counting.
    0 Comments 0 Shares 219 Views
  • The manufacturer of Invitrogen Countess Automated Cell Counter is Invitrogen. Model is Countess Automated Cell Counter. The Countess™ Automated Cell Counter is a benchtop automated cell counter that uses trypan blue staining for cell counting and viability measurements. https://www.ste-mart.com/invitrogen-countess-automated-cell-counter-invitrogen-115561.htm
    The manufacturer of Invitrogen Countess Automated Cell Counter is Invitrogen. Model is Countess Automated Cell Counter. The Countess™ Automated Cell Counter is a benchtop automated cell counter that uses trypan blue staining for cell counting and viability measurements. https://www.ste-mart.com/invitrogen-countess-automated-cell-counter-invitrogen-115561.htm
    WWW.STE-MART.COM
    Invitrogen Countess Automated Cell Counter, Invitrogen - STEMart
    Invitrogen Countess Automated Cell Counter, Invitrogen. For cell count, labelling of fluorescent probes, expression of fluorescent proteins, transfection efficiency and cell viability, etc.
    0 Comments 0 Shares 172 Views
  • Cytotoxicity Testing
    Cytotoxicity testing is a sensitive method to assess the biocompatibility of a material extracted through a specific cell culture media following exposure of the extracted fluid to L929 cells. This test is performed on raw materials in the manufacturing process, all medical devices contacting patients, and devices undergoing a sterilization validation. STEMart provides a wide range...
    0 Comments 0 Shares 542 Views
More Stories